APPROVALS/REGISTRATIONS:
- NSN Code for NATO Cataloging, Spanish Armed Forces: 6850-33-201-9456 (5 L), 6850-33-203-5723 (10 L), 6850-33-203-5724 (5 L).
- Product registered with the National Institute of Toxicology.
PROPERTIES:
Primarily used as pure antifreeze for circulating water systems and also in de-icing compounds.
TECHNICAL CHARACTERISTICS:
- Appearance: Phosphorescent green liquid, odorless, hygroscopic, sweet-tasting, and water-soluble. Miscible with aliphatic alcohols, aldehydes, and ketones. Contains ethylene glycol.
- Color (ASTM D1209): 10 (colorless) or phosphorescent green.
- Specific Gravity: 1.1
- Boiling Range: 175-180°C
- Acidity: 0.003
- Water Content: 0.3
- Ash Content: 0.002
- Sulfates: None
- Chlorides: None
- Corrosion Inhibitors: Contains.
PROTECTION FACTOR:
Temperature |
Concentration |
Vol % |
Weight % |
-10°C |
22% |
VOL |
25% |
-18°C |
32% |
VOL |
36% |
-20°C |
34% |
VOL |
38% |
-30°C |
40% |
VOL |
45% |
-40°C |
50% |
VOL |
55% |
APPLICATIONS:
For circulating water systems and in de-icing compounds.
INSTRUCTIONS FOR USE:
Prepare the recommended dilution based on the desired level of protection, ensuring to know the flow rate of the circulating water system and adding the calculated amount of antifreeze accordingly.
RECOMMENDATIONS:
Ensure complete recirculation for perfect homogenization.
IMPORTANT: QUEMDIZ products are guaranteed against manufacturing defects. The information, recommendations, specifications, usage methods, and dosages reflected in this document are considered correct and are based on data obtained through our own research. However, this does not necessarily mean they are the most suitable for every client, but rather a general guideline. It is always recommended to conduct preliminary tests before use for each specific application. Additionally, since QUEMDIZ does not have direct or continuous control over how and where its products are applied, it cannot accept direct or indirect responsibilities arising from their use unless there is assurance that QUEMDIZ's recommendations and specifications have been followed. This document may be modified without prior notice.