Probe diameter: The probe has a diameter of 10 mm, but at the end where the sensor is located, it has a section of 13 mm. The space required for the probe to pass must be a minimum of 13 mm.
The equipment is pre-calibrated with new oil to use it as a reference. The equipment measures the temperature and analyses changes in the dielectric coefficient of the oil. The measurements are displayed on a scale of 0 to 100%.
Between 0 and 39%, the oil is in compliance.
Between 40% and 59%, it is approaching the change interval.
Between 60% and 100%, the oil is no longer useful.
The kit includes a viscometer (Viscoprak) to also analyse the oil viscosity.
The equipment displays measurements only on the screen, so they should be recorded manually in a logbook.
Advantages:
- Measurement directly on the oil filter without the need to take a sample.
- Result after 5 seconds on the display.
- Easy handling.
Includes viscometer, protective case, and carrying case.